  Datasheet File OCR Text:
 CORCOM Product Guide Smallest Filtered Power Entry Modules with Metric Fuseholders
GG/HG Series
UL Recognized CSA Certified VDE Approved
HG1/GG1 GG8
GG Series
The GG series power entry modules combine the functions of a general purpose RFI filter with an IEC power cord connector and single or dual metric fusing, in the smallest possible panel space. A choice of .250" terminals or wire leads is available for the load-side terminations. For maximum cost effectiveness, 6 amp models should be used for all applications rated 6 amps or less, unless the higher performance of the 3 amp models, or the much higher performance of the 1 amp models, is needed. Models with C-suffix additionally incorporate a ground choke1 to isolate the equipment chassis from external ground at RF frequencies.
Specifications
Maximum leakage current,each line-to-ground HG Models @ 120 VAC 60 Hz: 2A @ 250 VAC 50 Hz: 5A Hipot rating (one minute): line-to-ground line-to-line Operating frequency: Rated voltage (max.): Fuse (not included): GG Models .25 mA .42 mA 1550 VAC 1450 VDC 50/60 Hz 250 VAC Accepts one 5x20mm fuse (-1 models) or two 5 x 20 mm fuses (-2 models)
HG Series
A medical version of our GG series, these filters offer the same compact design but reduce the line-to-ground capacitance in order to meet UL 2601 patient care requirements. For more information on UL2601 specification, see Appendix C. Note: When using the models with an IEC connector, remember that the leakage current of the companion line cord, GA400, is more significant than that of the filter which may disqualify this line cord from use in patient care applications. Current Rating .01 GG/GS Models 1A 12 3A - - 6A HG Models 1A 12 3A - 6A -
Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit .05 23 10 1 23 10 4 Frequency-MHz .10 .15 .5 1 5 29 15 4 29 15 10 32 19 10 32 19 14 41 30 16 40 25 18 47 36 22 40 26 18 50 48 36 28 22 14 10 50 50 40 22 21 14 30 55 53 50 18 21 14
Electrical Schematics
GG/GS/HG
LINE Note 1 LOAD
Line-to-line in 50 ohm circuit Current Rating .01 1 1 1 1 1 1 .15 3 2 2 3 2 2 Frequency-MHz .5 1 3 5 14 11 10 26 30 30 23 14 13 35 30 30 41 25 23 35 30 30 47 38 33 35 30 30 10 50 44 39 27 30 30 30 44 40 42 20 30 30
Note 2
GG-C
LINE
Note 1 LOAD
Note 2
Resistor location for reference only. Note 1: Depicts single fuse for -1 models. Note 2: For HG delete line-to-ground capacitors. CAUTION: DO NOT ATTEMPT TO OPERATE A SINGLE-FUSED MODEL WITHOUT THE FUSE DOOR IN PLACE!
GG/GS Models 1A 3A 6A HG Models 1A 3A 6A
112
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com
CORCOM Product Guide Smallest Filtered Power Entry Modules with Metric Fuseholders (Continued)
GG/HG Series
Case Styles
GG1/HG1
D
C
EGS
C
E
D E A
A
B
B
Power Entry Modules
Recommended Panel Cutouts
GG / HG Front or Back Mount 1.14 29.0 GS / HGS Front Mount Only 1.24 31.5
Typical dimensions: Holes: .07 [1.8] Dia. Terminals: .250 [6.35] (3) Mounting Holes: .126 [3.20] Dia. (2)
1.30 33.0
1.29 32.8
GG8
Blue Green/Yellow Brown
1.417 36.0
for panel thickness .032-.080 [.81-2.03] Radius: 0.138 [0.35]
Case Dimensions
B C
.6 15.2
D E
A
Typical dimensions: Wire leads: 5.0 [127.0] Min. 18 AWG Mounting Holes: .126 [3.20] Dia. (2)
A Part No. (max) EGG1-1/EGG1-2/ 2.15 EHG1-2 54.5 EGG8-1/EGG8-2 2.02 EGG8C-1/EGG8C-2 51.1 EGS1-1/EGS1-2 2.13 EHGS1-2 54.0 EGG1C-1-1/EGG1C-2 2.45 62.23 *max
B (max) 1.13 28.7 1.13 28.7 1.13 28.7 1.13 28.7
C (max) 1.29 32.8 1.29 32.8 1.28 32.5 1.28 32.5
D
.015 .38
1.417 36.0 1.417 36.0 1.46* 36.0 1.46* 36.0
E (max) 1.76 44.7 1.76 44.7 1.42 36.1 1.42 36.1
Part Number1 RFI Filter Type2 Current Rating3 Metric Fuseholders 1EGG1-1 General Purpose2 1 1 1EGG1-2 General Purpose 1 2 1EGG8-1 General Purpose 1 1 1EGG8-2 General Purpose 1 2 1 1 1EGS1-1 General Purpose 2 General Purpose 1 1EGS1-2 3EGG1-1 General Purpose 3 1 3EGG1-2 General Purpose 3 2 3 1 General Purpose 3EGG8-1 3EGG8-2 General Purpose 3 2 3EGS1-1 General Purpose 3 1 3EGS1-2 General Purpose 3 2 General Purpose 6 1 6EGG1-1 2 6 General Purpose 6EGG1-2 1 6 General Purpose 6EGG8-1 6EGG8-2 General Purpose 6 2 6EGS1-1 General Purpose 6 1 6 2 General Purpose 6EGS1-2 1EHG1-2 Medical 1 2 3EHG1-2 Medical 3 2 6EHG1-2 Medical 6 2 1EHGS1-2 Medical 1 2 2 3 Medical 3EHGS1-2 2 6 Medical 6EHGS1-2 1 Ground choke available on general purpose models. Add suffix "C" (1EGG1C-1). Does not include EGS models. 2 General purpose filter for susceptibility applications. 3 Current rating @120 VAC and 250 VAC.
Load Side Terminations .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) 5.0 [127.0] Wire Leads 5.0 [127.0] Wire Leads .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) 5.0 [127.0] Wire Leads 5.0 [127.0] Wire Leads .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) 5.0 [127.0] Wire Leads 5.0 [127.0] Wire Leads .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) .250 [6.35] Terminals (3) .250 [6.35] Terminals (3)
113
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com


▲Up To Search▲   

 
Price & Availability of 1EHGS1-2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X